The Aerox quick donning diluter-demand oxygen mask is equipped with an oro-nasal carbon fiber facepiece, a mask-mounted diluter-demand regulator, an electret microphone, and an inflatable head harness.
Notes
The Aerox quick donning diluter-demand oxygen mask is equipped with an oro-nasal carbon fiber facepiece, a mask-mounted diluter-demand regulator, an electret microphone, and an inflatable head harness. The inflatable harness that allows donning with one hand in less than 5 seconds, when used with Aerox 4110-155 stowage cup (sold separately). Various connectors are available to fit most built-in oxygen systems. The diluter-demand oxygen mask is intended to be used by qualified crewmembers to an altitude of 40,000 feet (MSL).
Approved to TSO-C78a and TSO-C89a.
Head Harness: Inflatable Quick Comfort
Certified Altitude: 40,000 Feet Max (MSL)
Microphone Plug: PJ068
Oxygen System Requirements:
1. Aviation Oxygen per MIL-O-27210
2. Supply Press Range: 55 to 70 Psi * (0.37 to 0.48 Mpa)
3. Operating Temp Range: +20 0 to +1200 F ** (-290 to +490C)
4. Relative Humidity: 5 to 95 percent
5. Overhaul: Aerox recommends every 3 years.
* A minimum oxygen flow of 100 liters per minute (NTPD) at 55 to 70 Psi must be supplied to the mask.
** If the aircraft is to be exposed to extreme cold weather for a extended period the crew oxygen masks must be removed from the aircraft and stored in a warm place.
Each mask is custom made to order. Most faces fit a medium mask (99%). Small children or very petite faces will use a small. The large is oversized for very large people.
Ordering Instructions:
1: please specify Head Harness Size
2: please specify inlet hose length
3: please specify Connection Type
Approved to TSO-C78a and TSO-C89a.
Head Harness: Inflatable Quick Comfort
Certified Altitude: 40,000 Feet Max (MSL)
Microphone Plug: PJ068
Oxygen System Requirements:
1. Aviation Oxygen per MIL-O-27210
2. Supply Press Range: 55 to 70 Psi * (0.37 to 0.48 Mpa)
3. Operating Temp Range: +20 0 to +1200 F ** (-290 to +490C)
4. Relative Humidity: 5 to 95 percent
5. Overhaul: Aerox recommends every 3 years.
* A minimum oxygen flow of 100 liters per minute (NTPD) at 55 to 70 Psi must be supplied to the mask.
** If the aircraft is to be exposed to extreme cold weather for a extended period the crew oxygen masks must be removed from the aircraft and stored in a warm place.
Each mask is custom made to order. Most faces fit a medium mask (99%). Small children or very petite faces will use a small. The large is oversized for very large people.